Your search
Results 3 resources
-
BACKGROUND: Lipoedema is a symmetrically localised, painful hypertrophy of subcutaneous adipose tissue in the extremities with marked disproportion to the trunk, and almost exclusively affects females. Despite being first described over 80 years ago, the aetiology and pathogenesis of the disease are largely unknown and are currently the subject of intensive research efforts. METHODS: To summarise the current evidence-based literature on the cellular pathologies and aetiology of lipoedema, a PRISMA-based systematic review was conducted within the National Library of Medicine and Cochrane databases. RESULTS: A total of 53 studies were identified and included in this review. The results were classified and summarised into categories. CONCLUSION: Although there has been a significant increase in research activity and recent publication of extensive studies with a histological and molecular genetic focus, the fundamental aetiology and pathology of lipoedema remains largely unclear. The current data shows discrepancies across studies, particularly with regard to the "oedematous" component of lipoedema. The frequently present comorbidities "lymphoedema" and "obesity", primarily in advanced stages of lipoedema, complicate the diagnostic differentiation and clear definition of study cohorts in scientific research.
-
Whole-body three-dimensional surface imaging (3DSI) offers the ability to monitor morphologic changes in multiple areas without the need to individually scan every anatomical region of interest. One area of application is the digital quantification of leg volume. Certain types of morphology do not permit complete circumferential scan of the leg surface. A workflow capable of precisely estimating the missing data is therefore required. We thus aimed to describe and apply a novel workflow to collect bilateral leg volume measurements from whole-body 3D surface scans regardless of leg morphology and to assess workflow precision. For each study participant, whole-body 3DSI was conducted twice successively in a single session with subject repositioning between scans. Paired samples of bilateral leg volume were calculated from the 3D surface data, with workflow variations for complete and limited leg surface visibility. Workflow precision was assessed by calculating the relative percent differences between repeated leg volumes. A total of 82 subjects were included in this study. The mean relative differences between paired left and right leg volumes were 0.73 ± 0.62% and 0.82 ± 0.65%. The workflow variations for completely and partially visible leg surfaces yielded similarly low values. The workflow examined in this study provides a precise method to digitally monitor leg volume regardless of leg morphology. It could aid in objectively comparing medical treatment options of the leg in a clinical setting. Whole-body scans acquired using the described 3DSI routine may allow simultaneous assessment of other changes in body morphology after further validation.
Explore
Topic
- Lipedema (3)
- Open Access (2)
- Original studies and data (1)
Resource type
- Journal Article (3)
Publication year
-
Between 2000 and 2024
(3)
-
Between 2010 and 2019
(1)
- 2018 (1)
- Between 2020 and 2024 (2)
-
Between 2010 and 2019
(1)
Publication
- Open Access (2)